Bureau Veritas broadens its three-phase DC power EMC testing solution

4th November, 2013, Taiwan – Bureau Veritas Consumer Products Services, Electrical &Electronic Business Line, Taiwan (BVCPS E&E Taiwan) is pleased to announce that its three-phase and DC power testing facilities have been established  in Linkuo Lab located in Taiwan.   With the enhancing capability, Bureau Veritas can provide profound and specialized electromagnetic compatibility (EMC) testing solutions to its clients.

 

 

Manufacturers of electrical and electronic products have to comply with the relevant EMC standards and regulations during the product development process. Therefore, EMC testing is a determinant segment in product design. With its comprehensive EMC testing solution, BVCPS E&E Taiwan can assist customers to meet the regulations of EU, the United States, Canada, Taiwan, Japan, Australia, New Zealand and other countries in terms of three-phase and DC power products. The testing scope covers a wide range of products, such as power supply, UPS, inverter, Server, and other related equipments. Detailed testing standards and services are as follows.

 

 

BV CPS E&E Taiwan can help you to meet below global and EU standards 

IEC/EN 61000-3-2  

Limits for harmonic current emissions (equipment input current <=16A per phase)

IEC/EN 61000-3-3   

Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current 16 A per phase

IEC/EN 61000-3-12 

Limits for harmonic current emissions (equipment input current >16A per phase)

IEC/EN 61000-3-11 

Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current > 16 A per phase

IEC/EN 61000-4-4   

Electrical fast transient/burst immunity test

IEC/EN 61000-4-5   

Surge immunity test(Max 15kV)

IEC/EN 61000-4-11  

Voltage dips, short interruptions and voltage variations immunity tests(equipment input current <=16A per phase)

IEC/EN 61000-4-34  

Voltage dips, short interruptions and voltage variations immunity tests (equipment input current > 16 A per phase)

IEC/EN 61000-4-14  

Voltage fluctuation immunity Test (equipment input current < 16 A per phase)

IEC/EN 61000-4-17  

Ripple on d.c. input power port immunity test

IEC/EN 61000-4-27  

Unbalance, immunity test(equipment input current >16A per phase)

IEC/EN 61000-4-28  

Variation of power frequency, immunity test (equipment input current < 16 A per phase)

IEC/EN 61000-4-29  

Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests

IEC/EN 61000-2-2    

Compatibility levels for low-frequency conducted disturbances and signaling in public low-voltage power supply systems

 

 

BVCPS E&E Taiwan is specialized in the field of electrical and electronic testing and certification and aims to provide customers with comprehensive one-stop testing services.  With the well-established system for three-phase and DC power testing , BVCPS E&E Taiwan widely expand its EMC testing services in order to help customers reduce the cost of testing and certification, accelerate time to market, and  ensure product quality. Through this one-stop EMC testing solution of three-phase and DC power, BVCPS E&E Taiwan assists clients to make big gains in global market.

 

 

For more information of EMC testing soluction , please visit HERE.

 

| About Us | Services | Products | Seminar | News | Support | Customer | Career | Sitemap | Contact | Legeal Policy | Go Top |
To download or copy any part of the databases, please get the written agreement by Bureau Veritas Consumer Products Services Division, Electrical & Electronic Business Line, Taiwan. The copyright of linked title(s) or content(s) is owned by the original website.
Copyright BUREAU VERITAS CONSUMER PRODUCTS SERVICES(HONG KONG) LIMITED, TAOYUAN BRANCH.
All Rights Reserved. For Comment, Please contact eemarketing.tw@tw.bureauveritas.com.

Designed by WDD

.